Why is my furnace blowing exhaust out the water heater vent?

Running a furnace and water heater simultaneously can overload their shared vent pipe. Because the furnace uses an exhaust fan and the water heater does not, the furnace pushes its exhaust backward through the water tank and into the room. This blows hot air into the house and randomly trips the tank's high limit switch, leaving people at a loss for how to stop it even after opening windows for more air.

Overview
People affected3 accounts across 1 forum
Workarounds found5 items attempted
Community agreement40 total upvotes

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

Found another way around this?

Share your steps and trade-offs so fellow engineers don't have to reinvent the wheel. No account required.

  1. 1
    Installing carbon monoxide detectors near the utilities.
    Did this help you?
  2. 2
    Checking chimney and exterior vents for physical blockages.
    Did this help you?
  3. 3
    Blowing out the vent pipes with a leaf blower to clear partial clogs.
    Did this help you?
  4. 4
    Calling a professional HVAC technician to perform a combustion analysis.
    Did this help you?
  5. 5
    Opening a nearby window to let more air into the mechanical room
    Did this help you?
Tried another approach not listed above?+ Share your workaround ↑

In their words

Unedited, grouped by where they were said, most upvoted first within each place, each linked to the thread it came from.

r/hvacadvice3 people · November 2026

“I'm at a loss on what I can do to fix it. I've tried opening a window to let more air in but idk what else to do”source ↗

Outrageous_Care_6448 · r/hvacadvice · 43 upvotes

“The old one did the same thing. The furnace has a fan on the exhaust. The hot water tank does not. So anytime the furnace is running it will push exhaust through the hot water tank and likely cause the hi limit to trip on the tank cover randomly.”source ↗

AffectionateSwan4478 · r/hvacadvice · 5 upvotes

“But hot air is definitely felt around the hot water heater vent when both are running.”source ↗

MakingItElsewhere · r/hvacadvice · 2 upvotes

“Less to no hot air coming out of the hot water vent. Same when furnace only. Both seem to overload the pipe.”source ↗

MakingItElsewhere · r/hvacadvice · 1 upvotes