How to fix a leaky plumbing valve that doesn't fit a new faucet

Non-standard valve connections often fail to sit flush with new faucet lines, and older diverter stems may require specific replacement washers. Mismatched sizing prevents a proper watertight seal, forcing you to replace incompatible components or track down exact-fit washers.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

  1. 1
    using two wrenches to loosen and remove old nuts
  2. 2
    replacing the antique valve with a modern quarter-turn stop
  3. 3
    reusing the old compression nut if the thread pattern matches
  4. 4
    Guessing based on visual appearance of the cartridge or consulting plumbing forums.
  5. 5
    Taking out the cap to clean sediments
  6. 6
    Adjusting the water level
  7. 7
    Aligning and wiggling the cap until it stops leaking
  8. 8
    Replacing the entire fill valve
  9. 9
    Calling the city to shut off the water at the city-owned shutoff valve
  10. 10
    Replacing the valve or setting a new washer or stem in it
  11. 11
    trying a sharkbite valve
  12. 12
    soldering a male adapter onto the pipe and threading a female threaded shut off
  13. 13
    removing the escutcheon cover plate to gain extra room for cutting
  14. 14
    Replacing the fill valve entirely instead of attempting a hit-or-miss repair since they are inexpensive.
  15. 15
    Hire a professional plumber to handle the valve replacement and any necessary couplings.
  16. 16
    Opening the valve fully and backing it off 1/8 turn
  17. 17
    Replacing the entire valve with a new ball valve
  18. 18
    Taking the old cartridge to a supplier to match and replace it
  19. 19
    Hiring a plumber to turn off the water and extend the line
  20. 20
    Removing the top nut of the metal piping and screwing on a steel braided line without replacing the angle stop
  21. 21
    Getting an initial plumber inspection of the crawl space to map existing lines
  22. 22
    Checking for corrosion, leaks, galvanized sections, and water quality
  23. 23
    Gathering multiple quotes and asking about permits and access
  24. 24
    Considering PEX as a more practical choice in crawl spaces to manage costs

In their words

Unedited, most upvoted first, each linked to the thread it came from.

So the valve isn’t sitting flush on the connector to the faucet, meaning I gotta replace it.source ↗

ThatOldDuderino · r/Plumbing · 2 upvotes

Need help identifying this shower valve.source ↗

VagiUnum · r/Plumbing · 2 upvotes

Thus is under the kitchen sink. I think I'll hire a plumber to replace the valve.source ↗

Different_Compote504 · r/Plumbing · 2 upvotes

I have to eventually replace all the pipes run in my house they are 70+ year old copper I think. How do I know what is a good place to work with and what type of pipe to go with.source ↗

Interesting_Hat_5162 · r/Plumbing · 2 upvotes

My toilet has a flapper valve system, and the water is flowing out from the sides of the Fluidmaster valve cap.source ↗

I tried taking out the cap and cleaning the sediments, as well as adjusting the water level. How can I tell whether the cap is not put on correctly vs the cap needing replacement?source ↗

malacata · r/HomeMaintenance · 1 upvotes

So I FINALLY got this out of the wall. I *think* I just need a washer on the end of this diverter stem. But my question, I guess is really a two parter: 1) am I right? And 2) how do I know what size washer to get?source ↗

treehuggress · r/Plumbing · 1 upvotes

My only issue is the knob before the meter doesn't fully stop the flowsource ↗

Obvious_Figure8655 · r/Plumbing · 1 upvotes

If I cut at the indent, will there be enough room for install?source ↗

toejamking25 · r/Plumbing · 1 upvotes

This valve only rotates clock wise about 180 degrees and doesn’t shut off the cold water.source ↗

And I couldn’t move it past that and also it doesn’t rotate counter clockwise either.source ↗

Any more pressure, I fear it will break apart.source ↗

I am just trying to turn off the water to install RO.source ↗

AsparagusLive237 · r/Plumbing · 1 upvotes

Please tell me what needs replacing?source ↗

TabbyTabby0 · r/Plumbing · 1 upvotes

Is this crimped on? Or can I pull it off and replace with a push to connect shark bite?source ↗

PeePeeePooPoooh · r/Plumbing · 1 upvotes

It's 25 years old and the whole bathroom is getting redone, figured might as well replace it and attach a steel braided hose to the new toiletsource ↗

PeePeeePooPoooh · r/Plumbing · 1 upvotes

I live in a condo so there is no access from below...what you see here is what's available, rest of it is under concrete.source ↗

Is that my only option? Or can I remove the top nut of the metal piping and screw on a steel braided line without messing with the angle stop?source ↗

PeePeeePooPoooh · r/Plumbing · 1 upvotes

He quoted us for both but unfortunately couldn’t afford either. Trying to make it financially possible and start lookingsource ↗

Interesting_Hat_5162 · r/Plumbing · 1 upvotes

I'm trying to install a new compression quarter turn valve on toilet line but as you can see, half of it has been crimped from the ferrule ring stuck to it.source ↗

If i cut off the section that is crimped, will i still have enough room to install the new valve?source ↗

I tried putting a sharkbite valve on and it stayed stuck on, but when I turn on house water, water shot out from the connection.source ↗

toejamking25 · r/Plumbing

This valve is 13 years old and leaks at the threads when I open and close it.source ↗

I see there is a spot I can put a wrench on, but when I tried, it wouldn't unthread (worried I would snap the valve).source ↗

Randomuser19889 · r/Plumbing

Where this came up

People with this problem also raised