How to run ductwork through a load-bearing wall without weakening it

Routing supply plenums and vent hoods often requires cutting or notching framing members right where the duct needs to go. This leaves homeowners stuck between risking structural stability or sacrificing airflow with awkward bends and off-center runs.

Overview
People affected6 accounts across 3 forums
Workarounds found14 items attempted
Community agreement11 total upvotes

What the numbers show

Counted from the threads quoted below. How we count

  • The most recent one is from October 2026.
  • This comes up 11.0× more often in r/hvacadvice than across the site as a whole.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

14 items+ Contribute

Found another way around this?

Share your steps and trade-offs so fellow engineers don't have to reinvent the wheel. No account required.

  1. 1
    hire a structural engineer
    Did this help you?
  2. 2
    install a beam to distribute weight
    Did this help you?
  3. 3
    Using multiple elbows to route the duct around the framing obstacle
    Did this help you?
  4. 4
    Cutting the stud and installing a header to clear the path
    Did this help you?
  5. 5
    using offset elbows to route ductwork around the obstacle
    Did this help you?
  6. 6
    cutting the stud and building a header and footer
    Did this help you?
  7. 7
    Using a heat gun to make PEX flexible or letting it sit in the sun
    Did this help you?
  8. 8
    Snaking pipes through carefully
    Did this help you?
  9. 9
    Accepting the use of many couplings
    Did this help you?
  10. 10
    Reorienting the exhaust fan motor upward to route above the appliance
    Did this help you?
  11. 11
    Using duct elbows to offset the venting into an adjacent open wall bay
    Did this help you?
  12. 12
    Hiring a contractor to perform structural reframing
    Did this help you?
  13. 13
    Leaving the abandoned duct alone if it is already closed off
    Did this help you?
  14. 14
    Routing the cable through the duct but ensuring the ends are tightly sealed to prevent garage fumes from entering
    Did this help you?
Tried another approach not listed above?+ Share your workaround ↑

In their words

Unedited, grouped by where they were said, most upvoted first within each place, each linked to the thread it came from.

r/HomeImprovement2 people · September 2026 – October 2026

“I was originally going to vent straight back, but it turns out there is a stud directly in the center of where the hood will go (technically 12.5-14" from the right side, 30" cabinet), so I was planning on instead venting up into a 45 to go left, and then another 45 to go out the side and sneak around the stud.”source ↗

buttbutt420 · r/HomeImprovement · 3 upvotes

“I would like to add an exterior exhaust for our microwave but I’m concerned about the studs that are in the way.”source ↗

“It’d require reframing around the exhaust cutout on the interior side. My original intention was to do this on my own but I’m intimidated by the triple studs from a load bearing perspective.”source ↗

chucklehead32 · r/HomeImprovement · 1 upvotes
r/hvacadvice3 people · September 2026 – October 2026

“Im installing a furnace and complete new duct work in my new (very old) home and need to get my supply plenum to the other side of this wall.”source ↗

“I dont want to risk compromising the support since it requires me to notch/remove building material.”source ↗

kurdoge · r/hvacadvice · 2 upvotes

“I was originally going to vent straight back, but it turns out there is a stud directly in the center of where the hood will go (technically 12.5-14" from the right side), so I was planning on instead venting up into a 45 to go left, and then another 45 to go out the side.”source ↗

“Is that foolish and going to destroy my static pressure, or would that be reasonable since it's such a short run?”source ↗

buttbutt420 · r/hvacadvice · 1 upvotes

“I just noticed some strange duct in the closet is out from the return duct and it goes down to the garage.”source ↗

“What would it be used to be for?”source ↗

“Also can I use it as a path of ethernet cable for POE camera?”source ↗

kevmando · r/hvacadvice · 1 upvotes
r/Plumbing2 people · September 2026

“For copper you're basically playing operation, but with a drill and a lot of cussing. And yeah, sometimes the purse comes out and you just accept the couplings.”source ↗

nonstopliner583 · r/Plumbing · 2 upvotes

“Resi guys, how tf are you getting pipes in these studs??”source ↗

“My guys, what black magic are you working to get the pipes fed through a 16" gap without 100 couplings. So I need to break out my purse?”source ↗

Astabar · r/Plumbing · 1 upvotes

Where this came up

People with this problem also raised