Why do cooling coils keep freezing over?

Melting iced-over coils with a heat gun fails to fix the problem because they quickly refreeze even worse within a day. This leaves the unit struggling to reach its temperature set point, trapping owners with a system that won't stay cold and leaving them unsure where to go from there.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

  1. 1
    Turn off the unit to allow it to thaw and change the return air filter.
  2. 2
    Using a heat gun to melt ice on the coils
  3. 3
    Checking and clearing the drain hole with warm water
  4. 4
    Replacing the appliance due to high repair costs
  5. 5
    Turning the unit off to clear the frost and restarting it
  6. 6
    Bubble testing line set connections for leaks
  7. 7
    Weighing out the charge from a vacuum
  8. 8
    Clearing the condensate line with warm water and vinegar
  9. 9
    Installing a DIY p-trap
  10. 10
    Switching air filter types
  11. 11
    Running the fan to thaw the system
  12. 12
    Leaving the door open to increase airflow
  13. 13
    Checking and replacing air filters
  14. 14
    Calling shops from the nearest town to find technicians willing to travel to rural areas
  15. 15
    Switching to a different HVAC company instead of calling the original installers
  16. 16
    Contacting the manufacturer for assistance or a manufacturer's representative
  17. 17
    Requesting a static pressure test or complete load calculation
  18. 18
    letting the system thaw
  19. 19
    cleaning the outside unit
  20. 20
    checking if the blower fan is blowing and vents are open
  21. 21
    researching potential refrigerant leaks and warranties
  22. 22
    adding refrigerant charge
  23. 23
    checking piston and orifice sizing
  24. 24
    inspecting for restrictions
  25. 25
    Removing air filters to improve airflow
  26. 26
    Adding refrigerant and stop-leak products
  27. 27
    Getting quotes for entire system replacements

In their words

Unedited, most upvoted first, each linked to the thread it came from.

AC stopped cooling early last week. HVAC company added refrigerant (1 pound, I think?) and some “stop-leak” ($450 all told). A week later it froze as in the photo. Same company came out and said the stop-leak must not have been enough. Also, they couldn't just repair it, but I needed a whole new system because the refrigerant has been phased out (R-410A). They quoted $9,800 for a heat-pump and evaporator coil and everything.source ↗

makingbook · r/hvacadvice · 8 upvotes

Our freezer stopped getting to freezing temperatures a few days ago. It is a little cold, but not freezing.source ↗

I opened the back panel of inside the freezer and the first part of the coils was frozen over. I used a heat gun and melted it and it did not fix the issue. I checked the coils again today and it is way more frozen over than it was the other day.source ↗

I'm not sure where to go from here.source ↗

DIYSD518 · r/appliancerepair · 4 upvotes

Got home and my unit was struggling to meet SP.source ↗

Decided to go outside and check out my condenser and found it froze up.source ↗

sydr0xx · r/hvacadvice · 4 upvotes

One year ago we had a new ac installed, 10k it cost and every month to every other month we’ve had technicians come out because the ac randomly stops working because the unit freezes.source ↗

solitudemils · r/hvacadvice · 4 upvotes

Back in july our ac started leaking like crazy, with a brand new filter I had installed the weekend before.source ↗

It starts leaking, again, life got super busy so we just delt with the water for 3 weeks, we finally get a guy to come look at it, he says the drain pan is crackedsource ↗

Now it's freezing up every other daysource ↗

If anyone has any ideas I'd greatly appreciate it, we want to call another company but we don't have hundreds to spend on dingosis calls to hear "well it's probably the pan give us 2k"source ↗

Anxious_Weight_5029 · r/hvacadvice · 3 upvotes

The system has frozen up multiple times and has struggled to cool properly.source ↗

Dustin_peterz · r/hvacadvice · 2 upvotes

Went outside and saw that the liquid and suction line were frozen over.source ↗

Liquid line is frozen up again.source ↗

ANY ideas or points to check when I go out tomorrow would be SUPER appreciated.source ↗

McChickenX69 · r/hvacadvice · 1 upvotes

If the ducking airflow not exactly air tight would it be freezing like seen in the picture please advise me.source ↗

Gold_Onion_920 · r/hvacadvice · 1 upvotes

The problem is it freezes instantly as soon as I turn it on, it starts freezing instantly from the inside unit it doesn’t freeze from the outside unitsource ↗

Gold_Onion_920 · r/hvacadvice · 1 upvotes

The problem is I live in a really rule area like inside the woods and it’s hard for me to find somebody that’s willing to come out to the place look at itsource ↗

Gold_Onion_920 · r/hvacadvice · 1 upvotes

The outside unit itself, the copper lines, and the cooling coils inside all froze.source ↗

AB287461 · r/hvacadvice · 1 upvotes