Compression fitting wobbles and slides on undersized copper pipe

Some copper pipes have a smaller outer diameter than standard fitting interiors, which causes compression and press-fit connections to wobble instead of gripping tightly. This mismatch prevents the fitting from forming a proper seal, resulting in persistent leaks and assemblies that easily rotate or slide right off the pipe.

Overview
People affected3 accounts across 1 forum
Workarounds found7 items attempted
Community agreement19 total upvotes

What the numbers show

Counted from the threads quoted below. How we count

  • People have been saying this in most months since September 2026.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

Found another way around this?

Share your steps and trade-offs so fellow engineers don't have to reinvent the wheel. No account required.

  1. 1
    Removing the press fitting and soldering a new stub out with an MIP and threaded ball valve
    Did this help you?
  2. 2
    Wrapping the fitting with a rag and repressing in the same position
    Did this help you?
  3. 3
    Sweating or soldering a valve or male fitting onto the copper pipe instead
    Did this help you?
  4. 4
    Calling a professional plumber
    Did this help you?
  5. 5
    Sweat the joint to fill the gap with solder
    Did this help you?
  6. 6
    Use a female threaded adapter instead of a sweat fitting
    Did this help you?
  7. 7
    Remove the valve cartridge before heating
    Did this help you?
Tried another approach not listed above?+ Share your workaround ↑

In their words

Unedited, grouped by where they were said, most upvoted first within each place, each linked to the thread it came from.

r/Plumbing3 people · September 2026 – November 2026

“However, this copper had a smaller OD than any pro press or solder fitting ID than usual, causing it to wobble and not seal.”source ↗

jambaseven · r/Plumbing · 17 upvotes

“I actually tried that twice. It didn’t make a difference.”source ↗

jambaseven · r/Plumbing · 1 upvotes

“After replacing the valve, I cannot for the life of me get the compression fitting to work.”source ↗

“No matter what I do, the entire assembly still fairly easily rotates and slides on the copper pipe!”source ↗

“I can get it to a magic location where there's only a tiny slow weeping leak but move it a bit and the pipe slides out more and it's spraying again.”source ↗

AndyDentPerth · r/Plumbing · 1 upvotes

“I'm installing a Moen Posi-temp (with diverter) and am concerned with the excessively loose fit of the street 90 (its a tight space).”source ↗

“I've tried multiple fittings and they all have the same sloppy fit... but 1/2 pipe has a snug fit.”source ↗

Gancanagh1 · r/Plumbing