How to replace two-prong outlets with three-prong without rewiring

Older homes often lack the ground wires needed for standard three-prong receptacles, forcing homeowners to choose between expensive full-house rewires or finding code-compliant alternatives like GFCI protection. Without a proper ground or GFCI setup, homeowners are left trying unsafe workarounds or struggling to fit modern safety devices into shallow historical boxes.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

  1. 1
    installing a GFCI receptacle or breaker
  2. 2
    adding a separate ground wire if a crawlspace or basement is available
  3. 3
    leaving the ground screw empty on the new three-prong outlet
  4. 4
    Using surge protectors plugged into the damaged outlets
  5. 5
    making sure LINE hot and neutral are on the right screws
  6. 6
    Go into the crawl space, pull that wire out, put it into a box, splice a new Romex to it, mount the splice box, run new wire up the wall
  7. 7
    Mount a surface mount box to the wall at the floor level
  8. 8
    Secure that current box to the floor or wall, then use a 14 gauge extension cord
  9. 9
    Cut a small part of the basement drywall ceiling and wall out to run a new line
  10. 10
    Add an inline splice kit and pop a wall box above baseboard level

In their words

Unedited, most upvoted first, each linked to the thread it came from.

1950s home with two prong outlets. Can I add a new 3 prong and ground it to the receptacle box? I believe the ultimate fix is to rewire the home but I would prefer not to do that if possible.source ↗

SnooCrickets8169 · r/askanelectrician · 53 upvotes

We couldn’t fit GFCIs into our old boxes, so we protected it there.source ↗

Fionaver · r/askanelectrician · 4 upvotes

I have electrical wiring that is connected to an outlet coming out of my floor into an outlet. Probably 6 in or so of length in the wiring (see imgur link). This sits behind my couch in this room, but since I am doing a bunch of other renovations in the room I figured I would update this at the same time.source ↗

Medic1334 · r/HomeImprovement · 1 upvotes

Neither had a ground, and on the new outlets I just plugged them in the same as they were (top to top, bottom to bottom) leaving the green screw empty.source ↗

futhisplace · r/askanelectrician · 1 upvotes

Should I replace them or is it safe to use them?source ↗

Optimuslives1 · r/askanelectrician · 1 upvotes

I get no light on the GFCI, though my non contact voltage tester shows current running through the outlet.source ↗

InMyBackyardIsTaken · r/askanelectrician · 1 upvotes