How to replace two-prong outlets with three-prong without rewiring

Older homes often lack the ground wires needed for standard three-prong receptacles, forcing homeowners to choose between expensive full-house rewires or finding code-compliant alternatives like GFCI protection. Without a proper ground or GFCI setup, homeowners are left trying unsafe workarounds or struggling to fit modern safety devices into shallow historical boxes.

Overview
People affected16 accounts across 3 forums
Workarounds found28 items attempted
Community agreement78 total upvotes

What the numbers show

Counted from the threads quoted below. How we count

  • People have been saying this in most months since August 2026.
  • This comes up 98.2× more often in r/askanelectrician than across the site as a whole.

What people tried

Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.

28 items+ Contribute

Found another way around this?

Share your steps and trade-offs so fellow engineers don't have to reinvent the wheel. No account required.

  1. 1
    installing a GFCI receptacle or breaker
    Did this help you?
  2. 2
    adding a separate ground wire if a crawlspace or basement is available
    Did this help you?
  3. 3
    leaving the ground screw empty on the new three-prong outlet
    Did this help you?
  4. 4
    Using surge protectors plugged into the damaged outlets
    Did this help you?
  5. 5
    making sure LINE hot and neutral are on the right screws
    Did this help you?
  6. 6
    Go into the crawl space, pull that wire out, put it into a box, splice a new Romex to it, mount the splice box, run new wire up the wall
    Did this help you?
  7. 7
    Mount a surface mount box to the wall at the floor level
    Did this help you?
  8. 8
    Secure that current box to the floor or wall, then use a 14 gauge extension cord
    Did this help you?
  9. 9
    Cut a small part of the basement drywall ceiling and wall out to run a new line
    Did this help you?
  10. 10
    Add an inline splice kit and pop a wall box above baseboard level
    Did this help you?
  11. 11
    cleaning the area with a sponge and water
    Did this help you?
  12. 12
    pressing the reset button on a GFCI outlet
    Did this help you?
  13. 13
    replacing the switch and outlet entirely
    Did this help you?
  14. 14
    Replacing 2-prong outlets with GFCI 3-prong outlets
    Did this help you?
  15. 15
    Labeling GFCI outlets as 'no equipment ground' to pass inspection
    Did this help you?
  16. 16
    Using specialized breakers that trip on unsafe current
    Did this help you?
  17. 17
    Splice wires using a wire connector to create a pigtail for the new outlet
    Did this help you?
  18. 18
    Use a slim outlet model to fit restricted box depth
    Did this help you?
  19. 19
    taping the outlet cover to the wall with electrical tape
    Did this help you?
  20. 20
    Ensuring the first outlet in the circuit is a GFCI
    Did this help you?
  21. 21
    Swapping every outlet in the series
    Did this help you?
  22. 22
    Waiting for the receptacle to dry out
    Did this help you?
  23. 23
    Replacing the entire outdoor weather-resistant box and outlets
    Did this help you?
  24. 24
    experimenting with wire configurations
    Did this help you?
  25. 25
    snipping continuous wire loops
    Did this help you?
  26. 26
    Changing the plug directly
    Did this help you?
  27. 27
    put the old outlet back
    Did this help you?
  28. 28
    Copying the exact wiring configuration from the old outlet to the new one and hoping it works.
    Did this help you?
Tried another approach not listed above?+ Share your workaround ↑

In their words

Unedited, grouped by where they were said, most upvoted first within each place, each linked to the thread it came from.

r/askanelectrician12 people · August 2026 – October 2026

“1950s home with two prong outlets. Can I add a new 3 prong and ground it to the receptacle box? I believe the ultimate fix is to rewire the home but I would prefer not to do that if possible.”source ↗

SnooCrickets8169 · r/askanelectrician · 53 upvotes

“We couldn’t fit GFCIs into our old boxes, so we protected it there.”source ↗

Fionaver · r/askanelectrician · 4 upvotes

“I notice the outlets that are in series, sometimes, have an open ground.”source ↗

“Do I have to swap every outlet in the series in order for the series of outlets to be grounded properly?”source ↗

Traditional_Hornet91 · r/askanelectrician · 3 upvotes

“The actual light switch itself works fine but the power outlet does not, my friend who is a handyman came over and left this socket detector that says wether an outlet is good or faulty and when I tried using it it gave no signifier that power is going through it whatsoever.”source ↗

“I know it’s dirty but I don’t know what the most appropriate method to clean it was. I just used a sponge and water to scrape whatever stuff is”source ↗

“I have read other places that it’s likely a gfci outlet but I’m not super sure and won’t be unless I know how to clean it first so I can clearly see stuff.”source ↗

WontUseNooseYet · r/askanelectrician · 2 upvotes

“I’d like to replace them with GFCI outlets, but I’m confused as how to wire it.”source ↗

fadedmaps · r/askanelectrician · 2 upvotes

“Neither had a ground, and on the new outlets I just plugged them in the same as they were (top to top, bottom to bottom) leaving the green screw empty.”source ↗

futhisplace · r/askanelectrician · 1 upvotes

“Should I replace them or is it safe to use them?”source ↗

Optimuslives1 · r/askanelectrician · 1 upvotes

“I get no light on the GFCI, though my non contact voltage tester shows current running through the outlet.”source ↗

InMyBackyardIsTaken · r/askanelectrician · 1 upvotes

“The neutral wire comes into the outlet as a u-loop with one side going back into the wall and the other going into a wire nut with two other wires in it.”source ↗

“I am trying to replace this with a new outlet since the reset button stopped working”source ↗

“how to handle in a modern “lever edge” outlet that won’t accommodate the current u shape?”source ↗

everybodys_horse · r/askanelectrician · 1 upvotes

“It was hot enough to melt to cover. You're going to have to replace that anyway. $20 for new outlets is cheap insurance.”source ↗

James_T_S · r/askanelectrician · 1 upvotes

“So my daughter has great interest in making her own clothes and wanted to get a machine which I of course went off and bought her an old vintage machine .. great machine and will do what she wants to do but it’s on an EU plug at the moment and I wanted to swap it for a uk one .. is this a case of changing plug and away she goes or is it a case of internals/transformers/sparky stuff as well need to be changed .”source ↗

darrirl · r/askanelectrician · 1 upvotes

“Three wires: hot, cold , ground. But the hot and cold wires are each two wires looped but they’re not separated. The new outlet is push in style.”source ↗

Seamstress62 · r/askanelectrician
r/HomeMaintenance3 people · September 2026 – November 2026

“I was changing some outlets in my home yesterday when I came across one that was really confusing).”source ↗

“Anyway, when I opened it up, I saw that it had 3 white wires attached, 3 black wires, and 2 ground wires!?! WTH?!?”source ↗

“Maybe not the wisest thing, but I just swapped out the old receptacle for the new one I bought, copying the configuration”source ↗

“can anyone tell me (1) whether I messed up doing what I did and (2) why that thing looked so different than the other receptacles I changed”source ↗

Icy-Manufacturer3500 · r/HomeMaintenance · 4 upvotes

“when i moved in i didn’t notice this issue until i started using a hairdryer and it became a nuisance.”source ↗

“the casing for the screws keeping the outlet attached to the inner wall (sorry i don’t know the terms) are completely torn up, they won’t hold the screws at all.”source ↗

pickypanic · r/HomeMaintenance · 3 upvotes

“just remember to label the gfci "no equipment ground" or the inspector will ding you for it later, learned that one the hard way”source ↗

Beneficial-Report734 · r/HomeMaintenance · 2 upvotes
r/HomeImprovement1 person · September 2026

“I have electrical wiring that is connected to an outlet coming out of my floor into an outlet. Probably 6 in or so of length in the wiring (see imgur link). This sits behind my couch in this room, but since I am doing a bunch of other renovations in the room I figured I would update this at the same time.”source ↗

Medic1334 · r/HomeImprovement · 1 upvotes